<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://pra-ndm.epri.com/index.php?action=history&amp;feed=atom&amp;title=Internal_Flooding_PRA_Methods</id>
	<title>Internal Flooding PRA Methods - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://pra-ndm.epri.com/index.php?action=history&amp;feed=atom&amp;title=Internal_Flooding_PRA_Methods"/>
	<link rel="alternate" type="text/html" href="https://pra-ndm.epri.com/index.php?title=Internal_Flooding_PRA_Methods&amp;action=history"/>
	<updated>2026-11-23T10:30:46Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.39.8</generator>
	<entry>
		<id>https://pra-ndm.epri.com/index.php?title=Internal_Flooding_PRA_Methods&amp;diff=37&amp;oldid=prev</id>
		<title>Admin: 1 revision imported</title>
		<link rel="alternate" type="text/html" href="https://pra-ndm.epri.com/index.php?title=Internal_Flooding_PRA_Methods&amp;diff=37&amp;oldid=prev"/>
		<updated>2026-10-09T22:02:22Z</updated>

		<summary type="html">&lt;p&gt;1 revision imported&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;1&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 22:02, 9 October 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-notice&quot; lang=&quot;en&quot;&gt;&lt;div class=&quot;mw-diff-empty&quot;&gt;(No difference)&lt;/div&gt;
&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;</summary>
		<author><name>Admin</name></author>
	</entry>
	<entry>
		<id>https://pra-ndm.epri.com/index.php?title=Internal_Flooding_PRA_Methods&amp;diff=36&amp;oldid=prev</id>
		<title>en&gt;NDMAdmin: Created page with &quot;The following methods have been reported to EPRI as having been evaluated to determine whether they are NDMs or not.  Available information on the basis for determining that a...&quot;</title>
		<link rel="alternate" type="text/html" href="https://pra-ndm.epri.com/index.php?title=Internal_Flooding_PRA_Methods&amp;diff=36&amp;oldid=prev"/>
		<updated>2021-10-18T16:06:51Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;The following methods have been reported to EPRI as having been evaluated to determine whether they are NDMs or not.  Available information on the basis for determining that a...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;The following methods have been reported to EPRI as having been evaluated to determine whether they are NDMs or not.  Available information on the basis for determining that a method is or is not an NDM and a summary of any completed NDM Peer Reviews are included as provided to EPRI by the party making the determination or conducting the NDM Peer Review.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!    Date   !!        Title   	!!      Description	!! 	  Implementing Document	   !! 	Is this a “Newly Developed Method (NDM)”? 	!! 	Link to NDM Decision Justification 	!! 	Has a NDM Peer Review been conducted? 	!! 	Link to NDM Peer Review Public Summary		&lt;br /&gt;
|-&lt;br /&gt;
|               ||               ||               ||               ||               ||               ||               ||               |&lt;/div&gt;</summary>
		<author><name>en&gt;NDMAdmin</name></author>
	</entry>
</feed>