Human Reliability Analysis (HRA) Methods

From PRA NDM Repository
Revision as of 11:13, 17 July 2025 by NDMAdmin (talk | contribs)
Jump to navigation Jump to search

The following methods have been reported to EPRI as having been evaluated to determine whether they are NDMs or not. Available information on the basis for determining that a method is or is not an NDM and a summary of any completed NDM Peer Reviews are included as provided to EPRI by the party making the determination or conducting the NDM Peer Review.

Date Title Description Implementing Document Is this a “Newly Developed Method (NDM)”? Link to NDM Decision Justification Has a NDM Peer Review been conducted? Link to NDM Peer Review Public Summary
June 2025 All Credible Dependency Combinations in Tree (ACDCT) Y Y CA-MISC-038